Main Article Content

ID Afifah Batis ID Andika Aliviameita

Abstract

The choice of anticoagulants and the methods of homogenization are critical pre-analytical steps that can significantly influence the accuracy of laboratory results. This study aims to assess the differences in erythrocyte count and hemoglobin levels among blood samples processed with conventional anticoagulants and Vacutainer tubes, taking into account variations in secondary homogenization techniques. A laboratory experimental design was employed, utilizing 32 blood samples acquired from eight participants. The analysis was conducted using an automated hematology analyzer. Data were subjected to a Paired T-Test, indicating no significant differences in erythrocyte counts (p=0.617) and hemoglobin levels (p=0.510) between conventional EDTA samples that were homogenized four times and those homogenized eight times. However, a significant difference was noted in erythrocyte counts (p=0.018), while hemoglobin levels remained unaffected (p=0.393) in EDTA vacutainer samples subjected to four versus eight rounds of secondary homogenization. Additionally, a significant difference was found in both erythrocyte counts (p = 0.008) and hemoglobin levels (p < 0.0001) between conventional EDTA samples and those subjected to four rounds of secondary homogenization using vacutainers. Similarly, there was a significant difference in erythrocyte counts (p = 0.006) and hemoglobin levels (p = 0.014) between conventional EDTA samples and Vacutainer samples that underwent eight rounds of homogenization.


 Keywords: Blood Specimen Collection; EDTA; Erythrocyte; Hemoglobin; Secondary Homogenization

Downloads

Download data is not yet available.

Article Details

How to Cite
Batis, A., & Aliviameita, A. (2025). Variations in Erythrocyte Count and Hemoglobin Levels in Blood Samples Collected Using Conventional Anticoagulants and Vacutainers with Different Secondary Homogenization Techniques. Medical Technology and Public Health Journal , 9(2). https://doi.org/10.33086/mtphj.v9i2.7006
Section
Articles
EDTA Vacutainer, Conventional EDTA, Secondary Homogenization, Erythrocyte Count, Hemoglobin levels

References

Ayuningsih, W. N., Hayati, E., Nurhayati, B., & Noviar, G. (2023) ‘Pengaruh Waktu Simpan Darah dan Jenis Antikoagulan Terhadap Jumlah Retikulosit pada Suhu Lemari Es’, Jurnal Kesehatan Siliwangi, 4(1), pp. 404-411. Doi: 10.34011/jks.v4i1.1455. DOI: https://doi.org/10.34011/jks.v4i1.1455

Dewi, L.S., Sudarsono, T. A., Sulistiyowati, R., & Wardani, D. P. K. (2022) ‘Perbandingan Hasil Pemeriksaan Hitung Jumlah Eritrosit Menggunakan EDTA Konvensional dan Vacutainer’, Jurnal Surya Medika (JSM), 7(2), pp. 181-184. Doi: 10.33084/jsm.vxix.xxx. DOI: https://doi.org/10.33084/jsm.v7i2.2842

Dewi, R. A. M. (2017) ‘Perbedaan Nilai Hematokrit dengan Antikoagulan EDTA (Ethylene Diamine Tetraacetic Acid) Konvensional dan EDTA Vacutainer’, Karya Tulis Ilmiah, Analis Kesehatan STIKes ICMe Jombang.

Esaputri, R. H., Suhariyadi, Anggraini, A. D. (2022) ‘Pengaruh Volume Darah pada Tabung Vacutainer Kapasitas 3 ml Terhadap Jumlah Eritrosit dan Kadar Hemoglobin pada Anak-anak dan Orang Dewasa’, Jurnal Penelitian Kesehatan (JPK), 20(1), pp. 1-7. Doi: 10.35882/jpk.xxxx. DOI: https://doi.org/10.36568/jpk.v20i1.94

Faradilla, N. F. (2018) ‘Perbedaan Jumlah Trombosit dengan Pemberian Antikoagulan EDTA (Ethylene Diamine Tetraacetic Acid) Konvensional dan EDTA Vacutainer’, Karya Tulis Ilmiah, Analis Kesehatan STIKes ICMe Jombang.

Hariyanto, Hermawati, A. H., Prastama, H. Y. (2024) ‘Perbedaan EDTA Konvensional dan EDTA Vacutainer pada Pemeriksaan Kadar Hemoglobin’, Borneo Journal of Medical Laboratory Teknology, 6(2), pp. 614-620. DOI: https://doi.org/10.33084/bjmlt.v6i2.7102

Kuman, M. Y. (2019) ‘Perbedaan Jumlah Eritrosit, Leukosit, dan Trombosit pada Pemberian Antikoagulan Konvensional dan EDTA Vacutainer’, Karya Tulis Ilmiah, Analis Kesehatan Poltekkes Kemenkes Kupang.

Lippi, G., Pavesi, F., Benegiamo, A., & Pipitone, S. (2015) ‘What Do Hemolyzed Whole-Blood Specimens Look Like? Analysis with a Cella Vision DM 96 Automated Image Analysis System’ Journal of Laboratory Automation, 20(1), pp. 60-63. Doi: 10.1177/2211068214559644. DOI: https://doi.org/10.1177/2211068214559644

Mentari, I. N., Ariza, D., Halid, I. (2020) ‘Pemanfaatan Ekstrak Daun Seledri (Apium Graveolens) Sebagai Antikoagulan Pengganti EDTA (Ethylene Diamine Tetraacetic Acid) pada Pemeriksaan Jumlah Trombosit’, Jurnal Penelitian dan Kajian Ilmiah Kesehatan, 6(2), pp. 192-198.

Nuraeni, M., Septie, L. (2023) ‘Perbandingan Hasil Pemeriksaan Jumlah Eritrosit dengan Teknik Homogenisasi Sekunder Empat Kali dan Delapan Kali’, Jurnal Kesehatan Saelmakers PERDANA, 6(2), pp. 228-234. Doi: 10.32524/jksp.v6i2.989.

Sebayang, R., Sinaga, H., Hutabarat, M. S. (2021) ‘Homogenisasi Sekunder Terhadap Kadar Hemoglobin’, Jurnal Keperawatan Silampari, 5(1), pp. 444-452. Doi: 10.31539/jks.v5i1.3049. DOI: https://doi.org/10.31539/jks.v5i1.3049

Septie, L., Haiti, M., Ramadhani, U. R. (2022) ‘Homogenisasi Sekunder 4, 8 Kali dan Tanpa Homogenisasi Sekunder pada Pemeriksaan Trombosit’, Jurnal Kesehatan dan Pembangunan, 12(24), pp. 49-53. DOI: https://doi.org/10.52047/jkp.v12i24.146

Viani, D. G., Nuraeni, M., Haiti, M. (2022) ‘Jumlah Trombosit Dengan Teknik Homogenisasi Sekunder Inversi (Bolak-balik) 5 dan 8 kali’, Rakernas, Teknologi Laboratorium Medik, Universitas Katolik Musi Charitas.

Wahyuni, N., Aliviameita, A. (2021) ‘Comparisson of Erythrocyte Index Values of Venous and Capilary Blood’, Medicra (Journal of Medical Laboratory Science/Technology), 4(1), pp. 13-16. Doi: 10.21070/medicra.v4i1.895. DOI: https://doi.org/10.21070/medicra.v4i1.895

Winarzat, W. S. (2021) ‘Perbedaan Penggunaan Antikoagulan Na2EDTA, K2EDTA, dan K3EDTA Terhadap Profil Eritrosit yang Diperiksa Secara Automatic dengan Hematology Analyzer’, Skripsi, Analis Kesehatan Poltekkes Kemenkes Yogyakarta.

Afifah Batis, Prodi Teknologi Laboratorium Medis, Fakultas Ilmu Kesehatan, Universitas Muhammadiyah Sidoarjo

Andika Aliviameita, Prodi Teknologi Laboratorium Medis, Fakultas Ilmu Kesehatan, Universitas Muhammadiyah Sidoarjo